HINGE MOUNTED SAFETY INTERLOCK
DESIGNED…TAMPER RESISTANT…FAIL-TO-SAFE MECHANICAL DESIGN
WARNING THIS INTERL OCK SAFETY SWITCH MUST BE CONNECTED TO A CONTROL RELIABLE SAFETY CIRCUIT
GENERAL DESCRIPTION:
The SW-1625-AS safety switch are intended for use with machine guards, protective grating, covers and doors, which have to be closed for operational safety. This safety switch comply with regulations for position switches having positive break NC contacts for operator safety. The housing is diecast aluminium.; The SW-1625-AS enclosure has a NEMA rating of 1, 3, 4, 12 and 13. The Normally Closed ( N.C ) contacts are closed when the rotating shaft is at center position.
The safety switch is typically connected directly to the rotating shaft of the mechanical door gate. The normally closed contacts on the safety switch open after two degrees of rotation for the switches shaft.
Refer to KTI Form FKL5098R1 for Control Reliable Self-Checking, Fault Recognition Safety Circuit Control Module.
.
TECHNICAL DATA: SPECIFICATION:
.
Conformity to Standards: …...UL, CSA, IEC, 947, VDE 0660, GS-ET-15.
Housing & actuator flanges: ..Die cast aluminum with baked enamel finish.
Degree of protection: …..IP 67, meets NEMA-3, 4, 12 & 13 requirements.
Connections: ………………………...……....……Pressure wire terminals.
Contact rating: ……………………..…….....A600, 10A pilot duty, P 150.
Operating Temperature: ……………....-300 to 800 C ( -220 to + 1750 F ).
Mechanical Life: ………………………..…..….........1 Million Operations.
Angle at positive break: …………………………….............…..50 degrees
.
WARNING:.. Control reliability states that the control system shall be designed, constructed, and installed such that a single control component failure within the system does not prevent stopping action from taking place but will prevent successive system cycles until the failure has been corrected. This requirement pretends to all components functioning on the system including mechanical interlocking devices. The SW-1625-AS is mechanically designed to fail-safe however, self checking and fault recognition is a checking process that is preformed by the machine controlling system. If your control system does not meet the current self-checking requirement it is recommended that the SM-1471-AS safety-circuit control module be incorporated into your safety-circuit. Please refer to KTI form FKL5098R1 for safety circuit control module information!
.
SAFETY INTERLOCK SWITCH PART NO.#
.
.
(OLP#-185)...SW-1625-AS Hinge Mounted Rotary Safety Interlock Switch.
.
.
.
SAFETY INTERLOCK SWITCHES
DESIGNED…. TAMPER RESISTANT…FAIL-TO-SAFE MECHANICAL DESIGN
WARNING THIS INTERLOCK SAFETY SWITCH MUST BE CONNECTED TO A CONTROL RELIABLE SAFETY CIRCUIT
GENERAL DESCRIPTION:
.
The SW-1472-AS safety switch are intended for use with machine guards, protective grating, covers and doors, which have to be closed for operational safety. This safety switch comply with regulations for position switches having positive break NC contacts for operator safety. The housing is made of fiberglass rein-forced thermoplastic, which is self-extinguishing. The SW-1472-AS enclosure has a NEMA rating of 1, 3, 4, 6, 12 and 13.
The Normally Closed ( N.C ) contacts are closed when the key is inserted into the switch actuator. The safety switch and keys are sold separately. Typically the safety switch is mounted on a solid structure of the mechanical barrier and the key is mounted to the moving portion of the mechaniacl gate.Refer to KTI Form FKL5098R1 for Control Reliable Self-Checking, Fault Recognition Safety Circuit Control Module.
.
TECHNICAL DATA: SPECIFICATION:
.
Conformity to Standards: …...UL, CSA, IEC, 947, VDE 0660, GS-ET-15.
Housing & actuator flanges: ....….Glass-fiber reinforced self-extinguishing
Thermoplastic with stainless steel actuator.
Degree of protection: ….IP 67, meets NEMA-3, 4, 12 & 13 requirements.
Connections: ………………………...……..….…Pressure wire terminals.
Contact rating: ……………………..……....A600, 10A pilot duty, P 300.
Operating Temperature: ……………...-300 to 800 C ( -220 to + 1750 F ).
Mechanical Life: ……………………………..........10 Million Operations.
Actuator Key: ……………………………….………..……Stainless steel.
.
WARNING:.. Control reliability states that the control system shall be designed, constructed, and installed such that a single control component failure within the system does not prevent stopping action from taking place but will prevent successive system cycles until the failure has been corrected. This requirement pretends to all components functioning on the system including mechanical interlocking devices. The SW-1625-AS is mechanically designed to fail-safe however, self checking and fault recognition is a checking process that is preformed by the machine controlling system. If your control system does not meet the current self-checking requirement it is recommended that the SM-1471-AS safety-circuit control module be incorporated into your safety-circuit. Please refer to KTI form FKL5098R1 for safety circuit control module information!
.
.
SAFETY INTERLOCK SWITCH PART NO.#
.
(OLP#-186)...SW-1472-AS Safety Interlock mechanical guard switch.
(OLP#-187)...KY-1473-AS Actuator Key ( one required per interlock switch ).
(OLP#-188)...PG-1474-AS Required hole plug for unused wiring holes ( one required per interlock switch ).
.
. .
.
SOLENOID LOCKING INTERLOCK SAFETY SWITCH WITH CONTROL CONTACTS
WARNING THIS INTERLOCK SWITCH MUST BE CONNECTED TO A CONTROL RELIABLE SAFETY CURCUIT
GENERAL DESCRIPTION:
.
SW-1626-AS safety interlock switch comply with regulations for positive break NC contacts required in safety circuits. This device may be used on industrial and commercial equipment where hinged guards, protective covers and grating, or doors must be kept closed and locked into position to insure operator safety, even when a power failure occurs. This interlock switch will remain locked upon resumption of power.
.
OPERATION:
Closing the guard inserts the actuator key into the housing and locks the guard utilizing a knee lever system that latches a dead-point locking mechanism. As the actuator is inserted into the housing the locking lever also closes internal switch contacts. Once the door or gate is locked, energizing ( supplying voltage ) the solenoid unlocks the mechanism. When unlocked the internal switch contacts are re-opened.
.
WARNING!!!
Control reliability states that the control system shall be designed, constructed, and installed such that a single control component failure within the system does not prevent stopping action from taking place but will prevent successive system cycles until the failure has been corrected.
This requirement pretends to all components functioning on the system including mechanical interlocking devices. The SW-1626-AS is mechanically designed to fail-safe however, self checking and fault recognition is a checking process that is preformed by the machine controlling system. If your control system does not meet the current self-checking requirement it is recommended that the SM-1471-AS safety-circuit control module be incorporated into your safety-circuit. Please refer to KTI form FKL5098R1 for safety circuit control module information!
.
TECHNICAL DATA: SPECIFICATION:
.
Conformity Standards: UL, IEC 947, VDE 0660, GS-ET-19
Housing: Diecast aluminum
Connections: Pressure wire terminals
Switch Contact rating: 220V AC @ 5Amps
Switch contacts: 2 NO + 2 NC
Short circuit protection: 10A time delay fuse
Mechanical operation: 1 Million operations
Locking force: 560 lbs.
Solenoid voltage: 120V typical @ 50/60hz
Solenoid wattage: 10 watts
.
.
WARNING:.. Control reliability states that the control system shall be designed, constructed, and installed such that a single control component failure within the system does not prevent stopping action from taking place but will prevent successive system cycles until the failure has been corrected. This requirement pretends to all components functioning on the system including mechanical interlocking devices. The SW-1625-AS is mechanically designed to fail-safe however, self checking and fault recognition is a checking process that is preformed by the machine controlling system. If your control system does not meet the current self-checking requirement it is recommended that the SM-1471-AS safety-circuit control module be incorporated into your safety-circuit. Please refer to KTI form FKL5098R1 for safety circuit control module information!
.
.
SAFETY INTERLOCK SWITCH PART NO.#
.
(OLP#-189)...SW-1626-AS Solenoid Locking Safety Switch.
(OLP#-190)...KY-1627-AS Actuator X axis swivel key ( one required per solenoid interlock ).
.
.